-
Hot sale Explosion Proof Led Lights - ESL102 Series Explosion-proof Emergency Lightings – Sunleem
Model Code Compliance Standard EN60079-0:2012+A11:2013, EN60079-1:2014, EN60079-5:2015, EN60079-7:2015, EN60079-11:2012, EN60079-31:2014 Technical Parameters Rated voltage: AC 220V 50Hz Lamp: LED DC3.0 – DC3.4V Rated power: 4W Emergency time: ≥ 90min Emergency power: 4W Emergency switch time: ≤ 0.25s Battery charging time: ≤ 24h Outline and Mounting Dimensions -
OEM/ODM Supplier Tri Proof Led Light - EJB102 Series Explosion-proof Junction Box – Sunleem
ATEx Cert. No.:SEX 20 ATEX 0416X IECEx Cert. No.: IECEx SEV 20.0015X Compliance Standard IEC 60079-0:2017,EN 60079-0:2018 IEC 60079-1:2014,EN 60079-1:2014 IEC 60079-31:2013,EN 60079-31:2014 Technical Parameters IP code:IP66 Corrosion resistance:WF2 Rated voltage:Max.1000VAC,50/60Hz Rated current:Max.150A Type of terminal: Dimensions Installation Method 1 Method 2 -
New Fashion Design for Explosion Proof Light Fittings - BZD130 Series Explosion-proof LED Lighting – Sunleem
Model Code Selection Table Compliance Standard IEC 60079-0:2011, IEC 60079-1:2014, IEC 60079-31:2013. EN 60079-0:2012+A11:2013, EN 60079-1:2014, EN 60079.-31:2014 Technical Parameters Luminous efficiency : ≥120lm/W Power factor : >0.95 Color temperature : 5500K~6500K Color rending index : Ra >75 IP code : IP66 Corrosion resistance : WF2 Ambient temperature : -40℃≤Ta≤+55℃ Dimensions and Photometry Outline and Mouting Dimensions -
Renewable Design for Cooper Lighting Explosion Proof Led - EFL708 Series Explosion-proof LED Linear Lightings – Sunleem
Compliance Standard IEC60079-0:2017,IEC60079-1:2014,IEC60079-7:2015,IEC60079-18:2014,IEC60079-31:2013. EN60079-0:2018,EN60079-1:2014,EN60079-7:2015,EN60079-18:2015EN60079-31:2014 Model Code Selection Table Technical Parameters Work ambient temperature: -55°C ~ +55°C without emergency device -20°C ~ +55°C with emergency device Rated voltage of LED Driver: 90 ~ 305VAC 50/60Hz Rated voltage of emergency power: 90~250VAC 50/60Hz Dimensions and Photometry Installation -
China wholesale Explosion-Proof Light - ZXF8030/51 Explosion Proof Corrosion Resistance Switches (IIC, tD) – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6 ; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, textile, military industries etc. Model Code Features Enclosure is increased safety and is made from GRP with good appearance and heat stability, and it has t... -
Factory Free sample Fluorescent Tube Light Bulbs - ESL101 Series Explosion-proof Emergency Lightings – Sunleem
Model Code Compliance Standard EN60079-0:2012+A11:2013, EN60079-1:2014, EN60079-7:2015, EN60079-11:2012,EN60079-31:2014 Technical Parameters Rated voltage: AC 220V 50Hz Lamp: LED Rated power: 2W Emergency time: ≥ 90min Emergency power: 2W Emergency shaft time: 0.25s Battery charging time: ≤24h Cable entry: G3/4″ Corrosion resistance: WF1 Cable outer diameters: Ф9mm~Ф14mm. Type Dimension -
Reliable Supplier Battery Powered Explosion Proof Lighting - ELL136 Series Explosion-proof LED Lighting – Sunleem
Model Code Compliance Standard EN60079-0:2012+A11:2013,EN60079-1:2014, EN60079-7:2015,EN60079-13:2015,EN60079-31:2014 Technical Parameters Working voltage: AC 200~240V, 50/60Hz(Special needs please note) Branket: 60W,100W,120W,150W,180W,200W,250W,300W Streeylight type: 60W,100W,120W,150W,180W,200W Lamp: LED Corrosion resistance:WF1 WF2 IP code: IP66 Ambient temperature: -40℃≤Ta≤+40℃ Luminnous efficiency: >100Lm/W Cable outer diameters: Ф9m~Ф15mm Power factor: 0.90 Cable entry: G1/2”(Brack... -
Best quality Atex Led - EJB102 Series Explosion-proof Junction Box – Sunleem
ATEx Cert. No.:SEX 20 ATEX 0416X IECEx Cert. No.: IECEx SEV 20.0015X Compliance Standard IEC 60079-0:2017,EN 60079-0:2018 IEC 60079-1:2014,EN 60079-1:2014 IEC 60079-31:2013,EN 60079-31:2014 Technical Parameters IP code:IP66 Corrosion resistance:WF2 Rated voltage:Max.1000VAC,50/60Hz Rated current:Max.150A Type of terminal: Dimensions Installation Method 1 Method 2 -
2018 High quality Requirements For Explosion Proof Lighting - ZXF8030/51 Explosion Proof Corrosion Resistance Switches (IIC, tD) – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6 ; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, textile, military industries etc. Model Code Features Enclosure is increased safety and is made from GRP with good appearance and heat stability, and it has t... -
Wholesale Explosion Proof Flood Lamp Light - EJB102 Series Explosion-proof Junction Box – Sunleem
ATEx Cert. No.:SEX 20 ATEX 0416X IECEx Cert. No.: IECEx SEV 20.0015X Compliance Standard IEC 60079-0:2017,EN 60079-0:2018 IEC 60079-1:2014,EN 60079-1:2014 IEC 60079-31:2013,EN 60079-31:2014 Technical Parameters IP code:IP66 Corrosion resistance:WF2 Rated voltage:Max.1000VAC,50/60Hz Rated current:Max.150A Type of terminal: Dimensions Installation Method 1 Method 2 -
China Supplier Explosion Proof Recessed Lighting - Manufacturer of China Atex Explosion-Proof 150W LED Flood Lights for Feed / Chemical/Oil/ Factory – Sunleem
We usually perform being a tangible workforce making sure that we will give you the most beneficial excellent plus the finest selling price for Manufacturer of China Atex Explosion-Proof 150W LED Flood Lights for Feed / Chemical/Oil/ Factory, We value your inquiry, For more details, please get hold of us, we’ll reply you ASAP! We usually perform being a tangible workforce making sure that we will give you the most beneficial excellent plus the finest selling price for China LED Flood Li... -
Personlized Products Led Explosion Proof Flood Lighting - EFL708 Series Explosion-proof LED Linear Lightings – Sunleem
Compliance Standard IEC60079-0:2017,IEC60079-1:2014,IEC60079-7:2015,IEC60079-18:2014,IEC60079-31:2013. EN60079-0:2018,EN60079-1:2014,EN60079-7:2015,EN60079-18:2015EN60079-31:2014 Model Code Selection Table Technical Parameters Work ambient temperature: -55°C ~ +55°C without emergency device -20°C ~ +55°C with emergency device Rated voltage of LED Driver: 90 ~ 305VAC 50/60Hz Rated voltage of emergency power: 90~250VAC 50/60Hz Dimensions and Photometry Installation