Home
Products
Explosion-Proof Lighting
Electrical Equipments
Installation Equipments
Chinese Certificate Products
Solutions
Company
About Us
Quality management
EEW academy
News
Contact
English
Chinese
Product
Home
Featured
Wholesale Explosion Proof Hand Held Lighting - ELL136 Series Explosion-proof LED Lighting – Sunleem
Model Code Compliance Standard EN60079-0:2012+A11:2013,EN60079-1:2014, EN60079-7:2015,EN60079-13:2015,EN60079-31:2014 Technical Parameters Working voltage: AC 200~240V, 50/60Hz(Special needs please note) Branket: 60W,100W,120W,150W,180W,200W,250W,300W Streeylight type: 60W,100W,120W,150W,180W,200W Lamp: LED Corrosion resistance:WF1 WF2 IP code: IP66 Ambient temperature: -40℃≤Ta≤+40℃ Luminnous efficiency: >100Lm/W Cable outer diameters: Ф9m~Ф15mm Power factor: 0.90 Cable entry: G1/2”(Brack...
inquiry
detail
Well-designed Explosion Proof Lighting Classification - ZXF8030/51 Explosion Proof Corrosion Resistance Switches (IIC, tD) – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6 ; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, textile, military industries etc. Model Code Features Enclosure is increased safety and is made from GRP with good appearance and heat stability, and it has t...
inquiry
detail
High Quality Explosion Proof Led Lighting Singapore - ELL601 Series Explosion-proof LED Lighting – Sunleem
Model Code Selection Table Compliance Standard IEC 60079-0:2017,IEC 60079-1:2014,IEC 60079-31:2013. EN60079-0:2018,EN60079-1:2014,EN60079-31:2014. Technical Parameters Power factor : >0.95 IP code : IP66 Corrosion resistance : WF2 Ambient temperature : -55℃≤Ta≤+55℃ Gland size : M25 X 1.5 T class: Technical Parameter
inquiry
detail
PriceList for Explosion Proof Industrial Led Lighting - EFL708 Series Explosion-proof LED Linear Lightings – Sunleem
Compliance Standard IEC60079-0:2017,IEC60079-1:2014,IEC60079-7:2015,IEC60079-18:2014,IEC60079-31:2013. EN60079-0:2018,EN60079-1:2014,EN60079-7:2015,EN60079-18:2015EN60079-31:2014 Model Code Selection Table Technical Parameters Work ambient temperature: -55°C ~ +55°C without emergency device -20°C ~ +55°C with emergency device Rated voltage of LED Driver: 90 ~ 305VAC 50/60Hz Rated voltage of emergency power: 90~250VAC 50/60Hz Dimensions and Photometry Installation
inquiry
detail
Short Lead Time for Fluorescent Light Ballast Voltage - EFL708 Series Explosion-proof LED Linear Lightings – Sunleem
Compliance Standard IEC60079-0:2017,IEC60079-1:2014,IEC60079-7:2015,IEC60079-18:2014,IEC60079-31:2013. EN60079-0:2018,EN60079-1:2014,EN60079-7:2015,EN60079-18:2015EN60079-31:2014 Model Code Selection Table Technical Parameters Work ambient temperature: -55°C ~ +55°C without emergency device -20°C ~ +55°C with emergency device Rated voltage of LED Driver: 90 ~ 305VAC 50/60Hz Rated voltage of emergency power: 90~250VAC 50/60Hz Dimensions and Photometry Installation
inquiry
detail
OEM/ODM Manufacturer Tri Proof - ESL101 Series Explosion-proof Emergency Lightings – Sunleem
Model Code Compliance Standard EN60079-0:2012+A11:2013, EN60079-1:2014, EN60079-7:2015, EN60079-11:2012,EN60079-31:2014 Technical Parameters Rated voltage: AC 220V 50Hz Lamp: LED Rated power: 2W Emergency time: ≥ 90min Emergency power: 2W Emergency shaft time: 0.25s Battery charging time: ≤24h Cable entry: G3/4″ Corrosion resistance: WF1 Cable outer diameters: Ф9mm~Ф14mm. Type Dimension
inquiry
detail
China New Product Fluorescent Tube Light Fittings - ELL601 Series Explosion-proof LED Lighting – Sunleem
Model Code Selection Table Compliance Standard IEC 60079-0:2017,IEC 60079-1:2014,IEC 60079-31:2013. EN60079-0:2018,EN60079-1:2014,EN60079-31:2014. Technical Parameters Power factor : >0.95 IP code : IP66 Corrosion resistance : WF2 Ambient temperature : -55℃≤Ta≤+55℃ Gland size : M25 X 1.5 T class: Technical Parameter
inquiry
detail
2018 China New Design Wind Cone Explosion Proof Internal Light - EJB Series Explosion-proof Empty enclosure – Sunleem
Compliance Standard IEC 60079-0:2017,EN 60079-0:2018 IEC 60079-1:2014,EN 60079-1:2014 IEC 60079-31:2013,EN 60079-31:2014 Technical Parameters Ambient temperature:-60℃≤Ta≤+60℃ Ambient temperature of sealing strip:-60℃≤Ta≤+100℃ Dimensions
inquiry
detail
100% Original Explosion Proof Light Bulbs - ZXF8030 Explosion Proof Corrosion Resistance Control Units – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, military industries, etc; Designed for the electrical control system for the users with function of sending order and monitoring; Different types can be des...
inquiry
detail
High Performance Explosion Proof Strip Light - EFL708 Series Explosion-proof LED Linear Lightings – Sunleem
Compliance Standard IEC60079-0:2017,IEC60079-1:2014,IEC60079-7:2015,IEC60079-18:2014,IEC60079-31:2013. EN60079-0:2018,EN60079-1:2014,EN60079-7:2015,EN60079-18:2015EN60079-31:2014 Model Code Selection Table Technical Parameters Work ambient temperature: -55°C ~ +55°C without emergency device -20°C ~ +55°C with emergency device Rated voltage of LED Driver: 90 ~ 305VAC 50/60Hz Rated voltage of emergency power: 90~250VAC 50/60Hz Dimensions and Photometry Installation
inquiry
detail
Hot Sale for Fluorescent Light For PlantsConverting Fluorescent Shop Lights To Led - ESL100 Series Explosion-proof Signal and Alarm Apparatus – Sunleem
Model Code Features Compliance Standard EN60079-0:2012+A11:2013, EN60079-1:2014, EN60079-7:2015, EN60079-11:2012, EN60079-31:2014. Technical Parameters Rated voltage: AC36/110/220V,50/60HzDC12/24/36V Lamp:LED Lamp power:≤2.5W Rated power:≤5W Sound Intensity:≥90dB Strobe frequency: 150times/min Corrosion resistance:WF1 Cable entries: G1/2″, G3/4″(pendant3) Cable outer diameters: φ6mm~10mm , φ9mm~14mm(pendant3). Outline and Mounting Dimensions
inquiry
detail
8 Year Exporter Fluorescent Strip Lights - AC Series Explosion Proof Plug and Receptacles – Sunleem
Details Application Designed for Explosive Atmospheres Zone1 and Zone2; Designed for Combustible Dust Zone21 and Zone22; Designed for IIA, IIB and IIC Groups Explosive Atmospheres; Designed for Temperature Classifications T1~T6; Designed for Explosive Hazardous Locations Such as Oil Refinery, Storage, Chemical, Pharmaceuticals, Military Industries Etc. Model Code Ordering References Rain Cover Should be Equipped If Used Outdoors. If Need Explosion Proof Plug and Receptacles, 16A,...
inquiry
detail
<<
< Previous
279
280
281
282
283
284
285
Next >
>>
Page 282 / 293