One of Hottest for Explosion Proof Lighting Globe - ESL100 Series Explosion-proof Signal and Alarm Apparatus – Sunleem
Model Code Features Compliance Standard EN60079-0:2012+A11:2013, EN60079-1:2014, EN60079-7:2015, EN60079-11:2012, EN60079-31:2014. Technical Parameters Rated voltage: AC36/110/220V,50/60HzDC12/24/36V Lamp:LED Lamp power:≤2.5W Rated power:≤5W Sound Intensity:≥90dB Strobe frequency: 150times/min Corrosion resistance:WF1 Cable entries: G1/2″, G3/4″(pendant3) Cable outer diameters: φ6mm~10mm , φ9mm~14mm(pendant3). Outline and Mounting Dimensions
inquiry
detail
China wholesale Explosion-Proof Light - ESL102 Series Explosion-proof Emergency Lightings – Sunleem
Model Code Compliance Standard EN60079-0:2012+A11:2013, EN60079-1:2014, EN60079-5:2015, EN60079-7:2015, EN60079-11:2012, EN60079-31:2014 Technical Parameters Rated voltage: AC 220V 50Hz Lamp: LED DC3.0 – DC3.4V Rated power: 4W Emergency time: ≥ 90min Emergency power: 4W Emergency switch time: ≤ 0.25s Battery charging time: ≤ 24h Outline and Mounting Dimensions
inquiry
detail
professional factory for James Lighting Explosion Proof - EJB102 Series Explosion-proof Empty enclosure – Sunleem
Compliance Standard IEC 60079-0:2017,EN 60079-0:2018 IEC 60079-1:2014,EN 60079-1:2014 IEC 60079-31:2013,EN 60079-31:2014 Technical Parameters IP code:IP66 Corrosion resistance:WF2 Dimensions Installation Method 1 Method 2
inquiry
detail
Super Lowest Price Tri-Proof - BJX Explosion Proof Junction Boxes – Sunleem
Caution Spotlight
inquiry
detail
High Performance Explosion Proof Strip Light - BX_Series Explosion Proof Distribution Boards – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T4/T5/T6; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, textile, printing, military industries etc. Used for power distribution in illumination or power circuit and on/off control or overhaul distribution o...
inquiry
detail
2018 Latest Design Explosion Proof Lighting Requirements - ZXF8030/51 Explosion Proof Corrosion Resistance Switches (IIC, tD) – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6 ; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, textile, military industries etc. Model Code Features Enclosure is increased safety and is made from GRP with good appearance and heat stability, and it has t...
inquiry
detail
Factory Supply Double Fluorescent Light - EBP Series Explosion-proof Stopping plug – Sunleem
Model Code Compliance Standard IEC 60079-0:2011, IEC 60079-1:2014, IEC 60079-7:2015, IEC 60079-31:2013. EN 60079-0:2012+A11:2013, EN 60079-1:2014, EN 60079.-7:2015, EN 60079-31:2014 Selection Table
inquiry
detail
High Performance Explosion Proof Light Parts - NGd Series Explosion- proof Flexible Conduit – Sunleem
Model Code Compliance Standard IEC 60079-0:2017, EN 60079- 0:2018 IEC 60079-1:2014, EN 60079-1:2014 IEC 60079-7:2015, EN 60079-7:2015 IEC 60079-31:2013, EN 60079-31:2014 Selection Table
inquiry
detail
Rapid Delivery for Explosion Proof Lighting Panels - EJB101 Series Explosion-proof Junction Box – Sunleem
ATEx Cert. No.:EPT 19 ATEX 3224X IECEx Cert. No.: IECEx EUT18.0032X EAC CU-TR Cert. No.: RU C-CN.AЖ58.B.00179/20 Compliance Standard IEC 60079-0:2011,EN 60079-0:2012+A11:2013 IEC 60079-1:2014,EN 60079-1:2014 IEC 60079-31:2013,EN 60079-31:2014 Technical Parameters Rated voltage:600V Ambient temperature:-55℃≤Ta≤+40℃/+55℃ IP code:IP66 Corrosion resistance:WF2 Dimensions All dimensions in mm Installation Method 1 Method2
inquiry
detail
100% Original Explosion Proof Light Bulbs - BDM Series Explosion-proof Cable Gland – Sunleem
BDM Series Explosion-proof Cable Gland Application Suitable for using in IIA,IIB,IIC Explosion hazardous gas zone1 and zone2. Combustible dust IIIA,IIIB,IIIC zone 21 and zone 22 IP code: IP66 Ex-Mark: Ex db IIC Gb, Ex eb IIC Gb,Ex tb IIIC Db. I II 2G Ex db IIC Gb, II 2D Ex tb IIIC Db ATEX Cert. No.: CML 17 ATEX 1026X IECEx Cert. No.: IECEx CML 17.0014X EAC CU-TR Cert. No.:RU C-CN.AЖ58.B.00320/20 Model Code Compliance Standard IEC 60079-0,IEC 60079-1,IEC 60079-7,IEC 60079-31. EN60079...
inquiry
detail
Factory wholesale Explosion Proof Warehouse Lighting - BJX8030 Explosion Proof Corrosion Resistance Junction Boxes (e,ia,tD) – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6 ; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals,militaryindustries, etc. Designed for wiring/ branching. Model Code Ordering References Normal supply for inlet device is in ordinary type. Otherrequire...
inquiry
detail
China Cheap price Battery Powered Fluorescent Light - ESL101 Series Explosion-proof Emergency Lightings – Sunleem
Model Code Compliance Standard EN60079-0:2012+A11:2013, EN60079-1:2014, EN60079-7:2015, EN60079-11:2012,EN60079-31:2014 Technical Parameters Rated voltage: AC 220V 50Hz Lamp: LED Rated power: 2W Emergency time: ≥ 90min Emergency power: 2W Emergency shaft time: 0.25s Battery charging time: ≤24h Cable entry: G3/4″ Corrosion resistance: WF1 Cable outer diameters: Ф9mm~Ф14mm. Type Dimension