Good User Reputation for Fluorescent Light Bulb Wattage - AH Explosion Proof Junction Boxes – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6 ; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, textile, printing, military industries etc. Model Code Ordering References Cable entry is G type, other requirements please indicate; Cable entry of li... -
OEM Customized Fluorescent Drop Light - BX_Series Explosion Proof Distribution Boards – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T4/T5/T6; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, textile, printing, military industries etc. Used for power distribution in illumination or power circuit and on/off control or overhaul distribution o... -
PriceList for Tri Proof Led - ESL100 Series Explosion-proof Signal and Alarm Apparatus – Sunleem
Model Code Features Compliance Standard EN60079-0:2012+A11:2013, EN60079-1:2014, EN60079-7:2015, EN60079-11:2012, EN60079-31:2014. Technical Parameters Rated voltage: AC36/110/220V,50/60HzDC12/24/36V Lamp:LED Lamp power:≤2.5W Rated power:≤5W Sound Intensity:≥90dB Strobe frequency: 150times/min Corrosion resistance:WF1 Cable entries: G1/2″, G3/4″(pendant3) Cable outer diameters: φ6mm~10mm , φ9mm~14mm(pendant3). Outline and Mounting Dimensions -
High Quality Explosion Proof Lighting - EJB101 Series Explosion-proof Junction Box – Sunleem
ATEx Cert. No.:EPT 19 ATEX 3224X IECEx Cert. No.: IECEx EUT18.0032X EAC CU-TR Cert. No.: RU C-CN.AЖ58.B.00179/20 Compliance Standard IEC 60079-0:2011,EN 60079-0:2012+A11:2013 IEC 60079-1:2014,EN 60079-1:2014 IEC 60079-31:2013,EN 60079-31:2014 Technical Parameters Rated voltage:600V Ambient temperature:-55℃≤Ta≤+40℃/+55℃ IP code:IP66 Corrosion resistance:WF2 Dimensions All dimensions in mm Installation Method 1 Method2 -
2018 Latest Design Fluorescent Light Starter Types - EJB101 Series Explosion-proof Junction Box – Sunleem
ATEx Cert. No.:EPT 19 ATEX 3224X IECEx Cert. No.: IECEx EUT18.0032X EAC CU-TR Cert. No.: RU C-CN.AЖ58.B.00179/20 Compliance Standard IEC 60079-0:2011,EN 60079-0:2012+A11:2013 IEC 60079-1:2014,EN 60079-1:2014 IEC 60079-31:2013,EN 60079-31:2014 Technical Parameters Rated voltage:600V Ambient temperature:-55℃≤Ta≤+40℃/+55℃ IP code:IP66 Corrosion resistance:WF2 Dimensions All dimensions in mm Installation Method 1 Method2 -
Special Price for Spiral Fluorescent Light Bulbs - AH Explosion Proof Junction Boxes – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6 ; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, textile, printing, military industries etc. Model Code Ordering References Cable entry is G type, other requirements please indicate; Cable entry of li... -
OEM Factory for Larson Explosion Proof Lights - BFD610 Series Explosion-proof Floodlightings – Sunleem
Model Code Selection Table Compliance Standard IEC 60079-0,IEC 60079-1,IEC 60079-7,IEC 60079-31. EN60079-0,EN60079-1,EN60079-7,EN60079-31 Technical Parameters Rated voltage: AC 220V, 50Hz IP code: IP66 Lamp holder: E40 Corrosion resistance: WF2 Outline and Mounting Dimensions -
Top Suppliers Atex Explosion Proof - BFD610 Series Explosion-proof Floodlightings – Sunleem
Model Code Selection Table Compliance Standard IEC 60079-0,IEC 60079-1,IEC 60079-7,IEC 60079-31. EN60079-0,EN60079-1,EN60079-7,EN60079-31 Technical Parameters Rated voltage: AC 220V, 50Hz IP code: IP66 Lamp holder: E40 Corrosion resistance: WF2 Outline and Mounting Dimensions -
Original Factory Fluorescent Light Bulb Types - BJX8030 Explosion Proof Corrosion Resistance Junction Boxes (e,ia,tD) – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6 ; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals,militaryindustries, etc. Designed for wiring/ branching. Model Code Ordering References Normal supply for inlet device is in ordinary type. Otherrequire... -
Factory Free sample Explosion Proof Led Drop Lights - BHJ Explosion Proof Unions – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 20, Zone 21 and Zone 22; Designed for II A, IIB, IIC groups explosive atmospheres; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, militaryindustries, etc. Different types and specifications are available for selection. Model Code Ordering References Normal type is G with same specification at each end; Metric, NPT and oth... -
Rapid Delivery for Explosion Proof Lighting Panels - BCG Explosion Proof Sealing Fittings – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for II A, IIB, IIC groups explosive atmospheres; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, militaryindustries,etc; Designed for segregating conduit in steel pipe wiring. Model Code Features Enclosure is die casted of aluminum alloy withhigh voltage electrostatic powder coated surface; With go... -
Rapid Delivery for Cooper Explosion Proof Lights - BFD610 Series Explosion-proof Floodlightings – Sunleem
Model Code Selection Table Compliance Standard IEC 60079-0,IEC 60079-1,IEC 60079-7,IEC 60079-31. EN60079-0,EN60079-1,EN60079-7,EN60079-31 Technical Parameters Rated voltage: AC 220V, 50Hz IP code: IP66 Lamp holder: E40 Corrosion resistance: WF2 Outline and Mounting Dimensions