Home
Products
Explosion-Proof Lighting
Electrical Equipments
Installation Equipments
Chinese Certificate Products
Solutions
Company
About Us
Quality management
EEW academy
News
Contact
English
Chinese
Product
Home
Featured
Manufacturing Companies for Explosion Proof Led Lighting Atex - ZXF8030/51 Explosion Proof Corrosion Resistance Switches (IIC, tD) – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6 ; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, textile, military industries etc. Model Code Features Enclosure is increased safety and is made from GRP with good appearance and heat stability, and it has t...
inquiry
detail
Chinese wholesale Explosion Proof Area Lighting - EJB Series Explosion-proof Empty enclosure – Sunleem
Compliance Standard IEC 60079-0:2017,EN 60079-0:2018 IEC 60079-1:2014,EN 60079-1:2014 IEC 60079-31:2013,EN 60079-31:2014 Technical Parameters Ambient temperature:-60℃≤Ta≤+60℃ Ambient temperature of sealing strip:-60℃≤Ta≤+100℃ Dimensions
inquiry
detail
Wholesale Price Explosion Proof Lights Vintage - BDM Series Explosion-proof Cable Gland – Sunleem
BDM Series Explosion-proof Cable Gland Application Suitable for using in IIA,IIB,IIC Explosion hazardous gas zone1 and zone2. Combustible dust IIIA,IIIB,IIIC zone 21 and zone 22 IP code: IP66 Ex-Mark: Ex db IIC Gb, Ex eb IIC Gb,Ex tb IIIC Db. I II 2G Ex db IIC Gb, II 2D Ex tb IIIC Db ATEX Cert. No.: CML 17 ATEX 1026X IECEx Cert. No.: IECEx CML 17.0014X EAC CU-TR Cert. No.:RU C-CN.AЖ58.B.00320/20 Model Code Compliance Standard IEC 60079-0,IEC 60079-1,IEC 60079-7,IEC 60079-31. EN60079...
inquiry
detail
professional factory for James Lighting Explosion Proof - EJB102 Series Explosion-proof Empty enclosure – Sunleem
Compliance Standard IEC 60079-0:2017,EN 60079-0:2018 IEC 60079-1:2014,EN 60079-1:2014 IEC 60079-31:2013,EN 60079-31:2014 Technical Parameters IP code:IP66 Corrosion resistance:WF2 Dimensions Installation Method 1 Method 2
inquiry
detail
Europe style for Explosion Proof Led Lighting Canada - ZXF8030 Explosion Proof Corrosion Resistance Control Units – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, military industries, etc; Designed for the electrical control system for the users with function of sending order and monitoring; Different types can be des...
inquiry
detail
Ordinary Discount Wall Mounted Explosion Proof Lights - ZXF8575 Explosion Proof Corrosion Resistance Plug and Receptacles (IIC, tD) – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, militaryindustries etc.; It is composed of plug and receptacle. Model Code Ordering References Connector is used for distant connection of cables. Curr...
inquiry
detail
Massive Selection for Fluorescent Emergency Light - EFL708 Series Explosion-proof LED Linear Lightings – Sunleem
Compliance Standard IEC60079-0:2017,IEC60079-1:2014,IEC60079-7:2015,IEC60079-18:2014,IEC60079-31:2013. EN60079-0:2018,EN60079-1:2014,EN60079-7:2015,EN60079-18:2015EN60079-31:2014 Model Code Selection Table Technical Parameters Work ambient temperature: -55°C ~ +55°C without emergency device -20°C ~ +55°C with emergency device Rated voltage of LED Driver: 90 ~ 305VAC 50/60Hz Rated voltage of emergency power: 90~250VAC 50/60Hz Dimensions and Photometry Installation
inquiry
detail
Fixed Competitive Price Fluorescent Batten Light - BDM Series Explosion-proof Cable Gland – Sunleem
BDM Series Explosion-proof Cable Gland Application Suitable for using in IIA,IIB,IIC Explosion hazardous gas zone1 and zone2. Combustible dust IIIA,IIIB,IIIC zone 21 and zone 22 IP code: IP66 Ex-Mark: Ex db IIC Gb, Ex eb IIC Gb,Ex tb IIIC Db. I II 2G Ex db IIC Gb, II 2D Ex tb IIIC Db ATEX Cert. No.: CML 17 ATEX 1026X IECEx Cert. No.: IECEx CML 17.0014X EAC CU-TR Cert. No.:RU C-CN.AЖ58.B.00320/20 Model Code Compliance Standard IEC 60079-0,IEC 60079-1,IEC 60079-7,IEC 60079-31. EN60079...
inquiry
detail
100% Original Explosion Proof Work Light - ESL100 Series Explosion-proof Signal and Alarm Apparatus – Sunleem
Model Code Features Compliance Standard EN60079-0:2012+A11:2013, EN60079-1:2014, EN60079-7:2015, EN60079-11:2012, EN60079-31:2014. Technical Parameters Rated voltage: AC36/110/220V,50/60HzDC12/24/36V Lamp:LED Lamp power:≤2.5W Rated power:≤5W Sound Intensity:≥90dB Strobe frequency: 150times/min Corrosion resistance:WF1 Cable entries: G1/2″, G3/4″(pendant3) Cable outer diameters: φ6mm~10mm , φ9mm~14mm(pendant3). Outline and Mounting Dimensions
inquiry
detail
China New Product Fluorescent Tube Light Fittings - ZXF8030 Explosion Proof Corrosion Resistance Control Units – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, military industries, etc; Designed for the electrical control system for the users with function of sending order and monitoring; Different types can be des...
inquiry
detail
Renewable Design for The Brick Explosion Proof Light - BFD610 Series Explosion-proof Floodlightings – Sunleem
Model Code Selection Table Compliance Standard IEC 60079-0,IEC 60079-1,IEC 60079-7,IEC 60079-31. EN60079-0,EN60079-1,EN60079-7,EN60079-31 Technical Parameters Rated voltage: AC 220V, 50Hz IP code: IP66 Lamp holder: E40 Corrosion resistance: WF2 Outline and Mounting Dimensions
inquiry
detail
100% Original Explosion Proof Light Bulbs - ESL102 Series Explosion-proof Emergency Lightings – Sunleem
Model Code Compliance Standard EN60079-0:2012+A11:2013, EN60079-1:2014, EN60079-5:2015, EN60079-7:2015, EN60079-11:2012, EN60079-31:2014 Technical Parameters Rated voltage: AC 220V 50Hz Lamp: LED DC3.0 – DC3.4V Rated power: 4W Emergency time: ≥ 90min Emergency power: 4W Emergency switch time: ≤ 0.25s Battery charging time: ≤ 24h Outline and Mounting Dimensions
inquiry
detail
<<
< Previous
45
46
47
48
49
50
51
Next >
>>
Page 48 / 293