Home
Products
Explosion-Proof Lighting
Electrical Equipments
Installation Equipments
Chinese Certificate Products
Solutions
Company
About Us
Quality management
EEW academy
News
Contact
English
Chinese
Product
Home
Featured
Fixed Competitive Price Metal Halide Explosion Proof Lighting - ESL102 Series Explosion-proof Emergency Lightings – Sunleem
Model Code Compliance Standard EN60079-0:2012+A11:2013, EN60079-1:2014, EN60079-5:2015, EN60079-7:2015, EN60079-11:2012, EN60079-31:2014 Technical Parameters Rated voltage: AC 220V 50Hz Lamp: LED DC3.0 – DC3.4V Rated power: 4W Emergency time: ≥ 90min Emergency power: 4W Emergency switch time: ≤ 0.25s Battery charging time: ≤ 24h Outline and Mounting Dimensions
inquiry
detail
Fixed Competitive Price Asp Explosion Proof Lighting - BZD130 Series Explosion-proof LED Lighting – Sunleem
Model Code Selection Table Compliance Standard IEC 60079-0:2011, IEC 60079-1:2014, IEC 60079-31:2013. EN 60079-0:2012+A11:2013, EN 60079-1:2014, EN 60079.-31:2014 Technical Parameters Luminous efficiency : ≥120lm/W Power factor : >0.95 Color temperature : 5500K~6500K Color rending index : Ra >75 IP code : IP66 Corrosion resistance : WF2 Ambient temperature : -40℃≤Ta≤+55℃ Dimensions and Photometry Outline and Mouting Dimensions
inquiry
detail
Trending Products Explosion Proof Led Sight Glass Light - ZXF8575 Explosion Proof Corrosion Resistance Plug and Receptacles (IIC, tD) – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, militaryindustries etc.; It is composed of plug and receptacle. Model Code Ordering References Connector is used for distant connection of cables. Curr...
inquiry
detail
High Quality for Led Tri Proof Light - ELL136 Series Explosion-proof LED Lighting – Sunleem
Model Code Compliance Standard EN60079-0:2012+A11:2013,EN60079-1:2014, EN60079-7:2015,EN60079-13:2015,EN60079-31:2014 Technical Parameters Working voltage: AC 200~240V, 50/60Hz(Special needs please note) Branket: 60W,100W,120W,150W,180W,200W,250W,300W Streeylight type: 60W,100W,120W,150W,180W,200W Lamp: LED Corrosion resistance:WF1 WF2 IP code: IP66 Ambient temperature: -40℃≤Ta≤+40℃ Luminnous efficiency: >100Lm/W Cable outer diameters: Ф9m~Ф15mm Power factor: 0.90 Cable entry: G1/2”(Brack...
inquiry
detail
Leading Manufacturer for Atex Explosion Proof Led Lights - EBP Series Explosion-proof Stopping plug – Sunleem
Model Code Compliance Standard IEC 60079-0:2011, IEC 60079-1:2014, IEC 60079-7:2015, IEC 60079-31:2013. EN 60079-0:2012+A11:2013, EN 60079-1:2014, EN 60079.-7:2015, EN 60079-31:2014 Selection Table
inquiry
detail
Factory wholesale Full Spectrum Fluorescent Lights - ELL601 Series Explosion-proof LED Lighting – Sunleem
Model Code Selection Table Compliance Standard IEC 60079-0:2017,IEC 60079-1:2014,IEC 60079-31:2013. EN60079-0:2018,EN60079-1:2014,EN60079-31:2014. Technical Parameters Power factor : >0.95 IP code : IP66 Corrosion resistance : WF2 Ambient temperature : -55℃≤Ta≤+55℃ Gland size : M25 X 1.5 T class: Technical Parameter
inquiry
detail
Lowest Price for Explosion Proof Marine Lighting - ELL136 Series Explosion-proof LED Lighting – Sunleem
Model Code Compliance Standard EN60079-0:2012+A11:2013,EN60079-1:2014, EN60079-7:2015,EN60079-13:2015,EN60079-31:2014 Technical Parameters Working voltage: AC 200~240V, 50/60Hz(Special needs please note) Branket: 60W,100W,120W,150W,180W,200W,250W,300W Streeylight type: 60W,100W,120W,150W,180W,200W Lamp: LED Corrosion resistance:WF1 WF2 IP code: IP66 Ambient temperature: -40℃≤Ta≤+40℃ Luminnous efficiency: >100Lm/W Cable outer diameters: Ф9m~Ф15mm Power factor: 0.90 Cable entry: G1/2”(Brack...
inquiry
detail
Wholesale Price IECEX - ZXF8575 Explosion Proof Corrosion Resistance Plug and Receptacles (IIC, tD) – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, militaryindustries etc.; It is composed of plug and receptacle. Model Code Ordering References Connector is used for distant connection of cables. Curr...
inquiry
detail
Best Price for Explosion Proof Emergency Exit Lights - AH Explosion Proof Junction Boxes – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6 ; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, textile, printing, military industries etc. Model Code Ordering References Cable entry is G type, other requirements please indicate; Cable entry of li...
inquiry
detail
Manufacturer for Explosion Proof Lighting Regulations - BJX8030 Explosion Proof Corrosion Resistance Junction Boxes (e,ia,tD) – Sunleem
Details Application Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6 ; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals,militaryindustries, etc. Designed for wiring/ branching. Model Code Ordering References Normal supply for inlet device is in ordinary type. Otherrequire...
inquiry
detail
Manufacturer of Cooper Explosion Proof Led Lightings - EJB102 Series Explosion-proof Empty enclosure – Sunleem
Compliance Standard IEC 60079-0:2017,EN 60079-0:2018 IEC 60079-1:2014,EN 60079-1:2014 IEC 60079-31:2013,EN 60079-31:2014 Technical Parameters IP code:IP66 Corrosion resistance:WF2 Dimensions Installation Method 1 Method 2
inquiry
detail
Fast delivery Led Tri-Proof Light - ESL100 Series Explosion-proof Signal and Alarm Apparatus – Sunleem
Model Code Features Compliance Standard EN60079-0:2012+A11:2013, EN60079-1:2014, EN60079-7:2015, EN60079-11:2012, EN60079-31:2014. Technical Parameters Rated voltage: AC36/110/220V,50/60HzDC12/24/36V Lamp:LED Lamp power:≤2.5W Rated power:≤5W Sound Intensity:≥90dB Strobe frequency: 150times/min Corrosion resistance:WF1 Cable entries: G1/2″, G3/4″(pendant3) Cable outer diameters: φ6mm~10mm , φ9mm~14mm(pendant3). Outline and Mounting Dimensions
inquiry
detail
<<
< Previous
96
97
98
99
100
101
102
Next >
>>
Page 99 / 293