Alaabta

  • ELL601 Taxanaha Qarax-Cilmiga LED

    ELL601 Taxanaha Qarax-Cilmiga LED

    Ku habboon in lagu isticmaalo IIA,IIB+H2 Aagga gaaska khatarta ah ee 1 iyo zone2.
    Siigada gubanaysa IIIA,IIB,IIIC zone 21 iyo zone 22
    Koodhka IP-ga: 1P66
    Ex-Mark: Ex db IIB+H2 T6/T5 Gb,Ex tb IIIC T80℃/T95℃ Db
    ATEx Cert. No: AÜV 19 ATEX 8446X
    Shahaadada IECEx No.: IECEx TUR 19.0066X
    Fasalka I Qaybta 1aad Kooxda B,C&D
    Fasalka I Qaybta 2aad Kooxda A,B,C&D
    Fasalka II Qaybta 1,2 Kooxda E,F&G

  • ELL136 Taxanaha Qarax-cadaynta LED

    ELL136 Taxanaha Qarax-cadaynta LED

    Ku haboon in lagu isticmaalo IIA,IIB,IIC Qarax gaaska khatarta ah1 iyo zone2.
    Siigada gubanaysa IIIA,IIB,IIIC zone 21 iyo zone 22
    Koodhka IP-ga: 1P66
    Ex-Mark: Ex de mb IIC T6 Gb,Ex tb IIIC T80℃ Db
    ATEx Cert. No.:ECM 18 ATEX 4867
    Shahaadada EAC CU-TR No: RU C-CN.AЖ58.B.00321/20

  • BZD130 Taxanaha Qarax-Cilmiga LED

    BZD130 Taxanaha Qarax-Cilmiga LED

    Ku haboon in lagu isticmaalo IIA,IIB,IIC Qarax gaaska khatarta ah1 iyo zone2.
    Siigada gubanaysa IIIA,IIB,IIIC zone 21 iyo zone 22
    Koodhka IP-ga: 1P66
    Ex-Mark: Ex db IIC T5 Gb,Ex tb IIIC T95℃ Db.
    ATEx Cert. No.:LCIE 17 ATEX 3062X
    Shahaadada IECEx No.: IECEx LCIE 17.0072X
    Shahaadada EAC CU-TR No: RU C-CN.AЖ58.B.00192/20

  • EFL708 Taxanaha Qarax-Caddaynta LED Iftiinno toosan

    EFL708 Taxanaha Qarax-Caddaynta LED Iftiinno toosan

    Ku habboon in lagu isticmaalo IIA, IIB, IIC Qarax gaaska khatarta ah Zone1 iyo Zone2.
    Siigada gubanaysa IIIA, IIIB, IIIC Zone 21 iyo Zone 22
    Koodhka IP: IP66.
    Ex-Mark:
    Ex db eb mb IIC T6 Gb, Ex tb IIIC T80°C Db.
    II 2 G Ex db eb mb IIC T6 Gb, II 2 D Ex tb IIIC T80°C Db.
    Shahaadada ATEX No.: ECM 19 ATEX 2352

  • ESL101 Taxanaha Qarax-Caddaynta Iftiinka Degdegga ah

    ESL101 Taxanaha Qarax-Caddaynta Iftiinka Degdegga ah

    Ku haboon in lagu isticmaalo IIA,IIB,IIC Qarax gaaska khatarta ah Zone1 iyo Zone2.
    Siigada gubanaysa IIIA,IIIB,IIIC Zone 21 iyo Zone 22
    Koodhka IP: IP66.
    Ex-Mark:
    Tusaale ahaan IIC T6 Gb, Ex tb IIIC T80°C Db.
    II 2G Ex de ib q IIC T6 Gb, II 2D Ex tb IIIC T80°C Db.
    Shahaadada ATEX No: ECM 18 ATEX 4869

  • ESL100 Taxanaha Calaamadaha Qaraxu-Cilmiga iyo Qalabka Alaarmiga

    ESL100 Taxanaha Calaamadaha Qaraxu-Cilmiga iyo Qalabka Alaarmiga

    Ku haboon in lagu isticmaalo IIA,IIB,IIC Qarax gaaska khatarta ah1 iyo zone2.
    Siigada gubanaysa IIIA,IIB,IIIC zone 21 iyo zone 22
    Koodhka IP: IP66
    Ex-Mark:
    Tusaale ahaan IIC T6 Gb, Ex tb IIIC T80℃ Db.
    II 2G Ex de ib IIC T6 Gb, II 2D Ex tb IIIC T80℃ Db.
    Shahaadada ATEX No.: ECM 18 ATEX 4868

  • ESL102 Taxanaha Qarax-Caddaynta Iftiinka Degdegga ah

    ESL102 Taxanaha Qarax-Caddaynta Iftiinka Degdegga ah

    Ku haboon in lagu isticmaalo IIA,IIB,IIC Qarax gaaska khatarta ah Zone1 iyo Zone2.
    Siigada gubanaysa IIIA,IIIB,IIIC Zone 21 iyo Zone 22
    Koodhka IP: IP65.
    Ex-Mark:
    Ex de ib q IIC T6 Gb, Ex tb IIIC T80°C Db.
    II 2G Ex de ib q IIC T6 Gb, II 2D Ex tb IIIC T80°C Db.
    Shahaadada ATEX No: ECM 18 ATEX 4870

  • Qalabka Iftiinka Iftiinka ee BHY

    Qalabka Iftiinka Iftiinka ee BHY

    Codsiga Faahfaahinta Loogu Naqdiyay Hawada Qaraxyada Aaga 1 iyo Aaga 2; Loogu talagalay IIA, IIB iyo IIC Kooxaha Jawiga Qaraxyada; Loogu talagalay Kala-saaridda Heerkulka T1 ~ T4; Waxaa loogu talagalay meelaha halista ah sida Kaydinta Warshada Sifeynta Saliidda, Kiimikada, Daawooyinka, Warshadaha Ciidamada, iwm Hal Tubbo oo Keliya ayaa ku Shaqeysa Xaalad Degdeg ah; Materiyada birta ah ee aan birta lahayn...
  • CCd92 Taxanaha Qarax-Cilmiyeedka

    CCd92 Taxanaha Qarax-Cilmiyeedka

    Ku habboon in lagu isticmaalo IIA, IIB, IIC Qarax gaaska khatarta ah Zone1 iyo Zone2.
    Siigada gubanaysa IIIA, IIIB, IIIC Zone 21 iyo Zone 22
    Koodhka IP: IP66
    Ex-Mark:
    Nooca CCd92-I: Ex d IIC T4 Gb, Ex tb IIIC T130°C Db
    Nooca CCd92-III: Ex d IIC T3 Gb, Ex tb IIIC T195°C Db.
    Nooca CCd92-I: II 2G Ex d IIC T4 Gb, II 2D Ex tb IIIC T130°C Db.
    Nooca CCd92-III: II 2G Ex d IIC T3 Gb, II 2D Ex tb IIIC T195°C Db.
    Shahaadada ATEX No.: LCIE 14 ATEX 3040X
    Shahaadada IECEx No.: IECEx LCIE 14.0034X
    Shahaadada EAC CU-TR No: RU C-CN.Aж58.B.00231/20

  • BFD610 Taxanaha Qarxa-caddayn Daadka

    BFD610 Taxanaha Qarxa-caddayn Daadka

    Ku haboon in lagu isticmaalo IIA, IIB+H2, Qarxinta gaaska halista ah Zone1 iyo Zone2
    Siigada gubanaysa IIIA, IIIB, IIIC Zone 21 iyo Zone 22
    Koodhka IP: IP66
    Ex-Mark:
    Ex IIB+H2 T4~T3 Gb, Ex tb IIIC T*°C Db.
    II 2G Ex IIB+H2 T4~T3 Gb, II 2D Ex tb IIIC T*°C Db.
    Shahaadada ATEX No.: LCIE 15 ATEX 3046X
    Shahaadada IECEx No.: IECEx LCIE 15.0037X
    Shahaadada EAC CU-TR No:RU C-CN.Aж58.B.00207/20