ELL601 Taxanaha Qarax-Cilmiga LED
Ku habboon in lagu isticmaalo IIA,IIB+H2 Aagga gaaska khatarta ah ee 1 iyo zone2.
Siigada gubanaysa IIIA,IIB,IIIC zone 21 iyo zone 22
Koodhka IP-ga: 1P66
Ex-Mark: Ex db IIB+H2 T6/T5 Gb,Ex tb IIIC T80℃/T95℃ Db
ATEx Cert. No: AÜV 19 ATEX 8446X
Shahaadada IECEx No.: IECEx TUR 19.0066X
Fasalka I Qaybta 1aad Kooxda B,C&D
Fasalka I Qaybta 2aad Kooxda A,B,C&D
Fasalka II Qaybta 1,2 Kooxda E,F&G -
ELL136 Taxanaha Qarax-cadaynta LED
Ku haboon in lagu isticmaalo IIA,IIB,IIC Qarax gaaska khatarta ah1 iyo zone2.
Siigada gubanaysa IIIA,IIB,IIIC zone 21 iyo zone 22
Koodhka IP-ga: 1P66
Ex-Mark: Ex de mb IIC T6 Gb,Ex tb IIIC T80℃ Db
ATEx Cert. No.:ECM 18 ATEX 4867
Shahaadada EAC CU-TR No: RU C-CN.AЖ58.B.00321/20 -
BZD130 Taxanaha Qarax-Cilmiga LED
Ku haboon in lagu isticmaalo IIA,IIB,IIC Qarax gaaska khatarta ah1 iyo zone2.
Siigada gubanaysa IIIA,IIB,IIIC zone 21 iyo zone 22
Koodhka IP-ga: 1P66
Ex-Mark: Ex db IIC T5 Gb,Ex tb IIIC T95℃ Db.
ATEx Cert. No.:LCIE 17 ATEX 3062X
Shahaadada IECEx No.: IECEx LCIE 17.0072X
Shahaadada EAC CU-TR No: RU C-CN.AЖ58.B.00192/20 -
EFL708 Taxanaha Qarax-Caddaynta LED Iftiinno toosan
Ku habboon in lagu isticmaalo IIA, IIB, IIC Qarax gaaska khatarta ah Zone1 iyo Zone2.
Siigada gubanaysa IIIA, IIIB, IIIC Zone 21 iyo Zone 22
Koodhka IP: IP66.
Ex-Mark:
Ex db eb mb IIC T6 Gb, Ex tb IIIC T80°C Db.
II 2 G Ex db eb mb IIC T6 Gb, II 2 D Ex tb IIIC T80°C Db.
Shahaadada ATEX No.: ECM 19 ATEX 2352 -
ESL101 Taxanaha Qarax-Caddaynta Iftiinka Degdegga ah
Ku haboon in lagu isticmaalo IIA,IIB,IIC Qarax gaaska khatarta ah Zone1 iyo Zone2.
Siigada gubanaysa IIIA,IIIB,IIIC Zone 21 iyo Zone 22
Koodhka IP: IP66.
Ex-Mark:
Tusaale ahaan IIC T6 Gb, Ex tb IIIC T80°C Db.
II 2G Ex de ib q IIC T6 Gb, II 2D Ex tb IIIC T80°C Db.
Shahaadada ATEX No.: ECM 18 ATEX 4869 -
ESL100 Taxanaha Calaamadaha Qaraxu-Cilmiga iyo Qalabka Alaarmiga
Ku haboon in lagu isticmaalo IIA,IIB,IIC Qarax gaaska khatarta ah1 iyo zone2.
Siigada gubanaysa IIIA,IIB,IIIC zone 21 iyo zone 22
Koodhka IP: IP66
Ex-Mark:
Tusaale ahaan IIC T6 Gb, Ex tb IIIC T80℃ Db.
II 2G Ex de ib IIC T6 Gb, II 2D Ex tb IIIC T80℃ Db.
Shahaadada ATEX No.: ECM 18 ATEX 4868 -
ESL102 Taxanaha Qarax-Caddaynta Iftiinka Degdegga ah
Ku haboon in lagu isticmaalo IIA,IIB,IIC Qarax gaaska khatarta ah Zone1 iyo Zone2.
Siigada gubanaysa IIIA,IIIB,IIIC Zone 21 iyo Zone 22
Koodhka IP: IP65.
Ex-Mark:
Ex de ib q IIC T6 Gb, Ex tb IIIC T80°C Db.
II 2G Ex de ib q IIC T6 Gb, II 2D Ex tb IIIC T80°C Db.
Shahaadada ATEX No: ECM 18 ATEX 4870 -
Qalabka Iftiinka Iftiinka ee BHY
Codsiga Faahfaahinta Loogu Naqdiyay Hawada Qaraxyada Aaga 1 iyo Aaga 2; Waxaa loogu talagalay IIA, IIB iyo IIC Kooxaha Jawiga Qaraxyada; Loogu talagalay Kala-saaridda Heerkulka T1 ~ T4; Waxaa loogu talagalay meelaha halista ah sida Kaydinta Warshada Sifeynta Saliidda, Kiimikada, Daawooyinka, Warshadaha Ciidamada, iwm Hal Tubbo oo Keliya ayaa ku Shaqeysa Xaalad Degdeg ah; Materiyada birta ah ee aan birta lahayn... -
CCd92 Taxanaha Qarax-Cilmiyeedka
Ku habboon in lagu isticmaalo IIA, IIB, IIC Qarax gaaska khatarta ah Zone1 iyo Zone2.
Siigada gubanaysa IIIA, IIIB, IIIC Zone 21 iyo Zone 22
Koodhka IP: IP66
Ex-Mark:
Nooca CCd92-I: Ex d IIC T4 Gb, Ex tb IIIC T130°C Db
Nooca CCd92-III: Ex d IIC T3 Gb, Ex tb IIIC T195°C Db.
Nooca CCd92-I: II 2G Ex d IIC T4 Gb, II 2D Ex tb IIIC T130°C Db.
Nooca CCd92-III: II 2G Ex d IIC T3 Gb, II 2D Ex tb IIIC T195°C Db.
Shahaadada ATEX No.: LCIE 14 ATEX 3040X
Shahaadada IECEx No.: IECEx LCIE 14.0034X
Shahaadada EAC CU-TR No: RU C-CN.Aж58.B.00231/20 -
BFD610 Taxanaha Qarxa-caddayn Daadka
Ku haboon in lagu isticmaalo IIA, IIB+H2, Qarxinta gaaska halista ah Zone1 iyo Zone2
Siigada gubanaysa IIIA, IIIB, IIIC Zone 21 iyo Zone 22
Koodhka IP: IP66
Ex-Mark:
Ex IIB+H2 T4~T3 Gb, Ex tb IIIC T*°C Db.
II 2G Ex IIB+H2 T4~T3 Gb, II 2D Ex tb IIIC T*°C Db.
Shahaadada ATEX No.: LCIE 15 ATEX 3046X
Shahaadada IECEx No.: IECEx LCIE 15.0037X
Shahaadada EAC CU-TR No:RU C-CN.Aж58.B.00207/20